Code Alerts

September 12, 2024

DensDeck Prime Storm X VSH Code Alert

This Code Alert focuses on Versico's continual search for high-performance and unique roofing system assemblies, extensive Very Severe Hail (VSH) testing has been completed at FM. The main VSH hail belt, as determined by FM, is in the Midwestern United States. However, other areas of the country have also shown interest in these robust assemblies.

November 18, 2022

California Minimum Insulation Requirements Sell Sheet

This sell sheet outlines the California Minimum Insulation Requirements for nonresidential and multifamily building roofs (low-slope) - 2022 Energy Code, Effective January 1, 2023

May 04, 2021

Versico Code Alert - FM1-29 Data Sheet - Summary Update Adhered Roofing Systems

This Code Alert will focus on the February 2020 FM 1-29 prescriptive enhancement requirements for insulation attachment using mechanical fasteners and ribbons of adhesive on adhered roofing systems.

April 09, 2021

Versico Code Alert - Mechanically Fastened Roofing Systems FM 1-29

This Code Alert will focus on the 2020 FM 1-29 performance-based and prescriptive enhancement requirements for membrane attachment on mechanically fastened roofing systems. This includes linear induction-welded systems.

October 07, 2020

Versico Code Alert - Very Severe Hail (VSH) – FM Approvals

As part of Versico Roofing Systems’ ongoing testing program for high-performance and unique roofing system assemblies, extensive Very Severe Hail (VSH) testing has been completed at FM. The main VSH hail belt (as determined by FM) is in the Midwest, but other areas of the country have shown interest in these robust assemblies.

October 07, 2020

Versico Code Alert - UL Class A - Wood Deck Applications

Versico has been committed to providing unique roofing solutions for the combustible deck market for many years, and its Class A fire rated assemblies have undergone many evolutions. The assemblies have steadily become more cost competitive, lighter in weight, and easier to install.

September 03, 2020

Code Alert - Versico FM 1-28 Summary Update

This Code Alert summarizes changes made to the FM 1-28 Property Loss Prevention Data Sheet, dated February 2020. One key change relates to roof zone dimensions to align with the ASCE 7-16 Design Standards. In some cases (depending on the roof dimensions, building height, and slopes), four zones may exist: interior, inner perimeter, outer perimeter, and corner zones.

September 03, 2020

Code Alert - Versico Re-Roofing Assemblies for Recover Applications

As part of Versico’s commitment to providing unique roofing solutions for the re-roofing market, this code alert spotlights economically viable options for recovering existing roofing systems. The assemblies are designed to offer simple, convenient, and value-based roofing solutions; allowing for quick installation with minimal disturbance or interference to the building operation. The existing substrates include asphaltic roofs, standing seam metal roofs, and single-ply membrane assemblies.

August 04, 2020

Code Alert - Versico Wind Uplift Testing for the Florida Market

As part of Versico’s continuous testing program for the State of Florida, testing was recently conducted on various TPO, PVC, and VersiFleece® membrane assemblies targeting the re-roofing/recover market.

There are no more results to display.